LANGUAGE
.Portuguese

 

 

 

 

 

 

 

 

 

 

 

.....................................

RESEL® ~ Polyurethane Resins BLOCKING
 

PRODUCT INFORMATION

These resins have been used for more than 15 years in the areas of Telecom and E/E.

Can be used to replace unsaturated Polyester, Epoxy resins, and silicone rubber

Advantages over other Polyurethane systems:

  • Low tension up to high hardness
  • Better resistance to water permeation (including water vapor)
  • Better hydrolytic stability
  • Better absorption to sound and impact
  • Improved handling properties (low sensibility to moisture, therefore less gassing)
  • Low viscosity, excellent adhesion, chemical resistance
  • Excellent electrical properties

Advantages over other systems:

  • Cost advantage over epoxy cured systems
 
Application Pictures
 

...................

 
 
SPECIFICATIONS RESIN RESEL®
 
RESEL® 301
Insulation of Electrical Materials .and in Cable Jacketing
Available only in liquid form. Used in encapsulation of electrical/electronic circuits.Color: amber or can be pigmented to customer's request.
Polyol : Pre-polymer Ratio 1 : 0,43
Gel time @ 25°C (ASTM D - 2471) 20 - 40 min
Cure time < 24 hours
Max cure temperature (ASTM D - 2471) <80°C
Density (20°C ) (ASTM D - 792) 0,9 - 1,0 g/m
Initial Mixture Viscosity (ASTM D-2669) 1000 -1850 cps
Hardness (ASTM D - 2240) 40 - 85 Shore "A"
Water Absorption % (ASTM D - 570 ) 1,0%
Volumetric Resistivity (ASTM D-257) 10 ohms/cm
Dielectric Constant @ 25°C (ASTM D - 150) 10 Hz 6.66
Dissipation Factor (ASTM D - 150) 10 Hz 0.099
Insulation Resistance (ASTM D-257) 10 ohms
 
RESEL® 302
Insulation of Electrical Materials .and in Cable Jacketing
Low viscosity resin for encapsulation of E/E circuits. Color: amber or can be pigmented to customer's request.
Polyol : Pre-polymer Ratio 1 : 0,7
Gel time @ 25°C (ASTM D - 2471) 15 - 30 min
Cure time < 24 hours
Max cure temperature (ASTM D - 2471) 95°C máx
Density (20°C ) (ASTM D - 792) 1,0 - 1,1 g/cm
Initial Mixture Viscosity (ASTM D-2669) 550 - 750 cps
Hardness (ASTM D - 2240) 70 - 90 Shore "D"
Water Absorption % (ASTM D - 570 ) 1,0%
Volumetric Resistivity (ASTM D-257) > 10 ohms/cm
Dielectric Constant @ 25°C (ASTM D - 150) 10 Hz
Dissipation Factor (ASTM D - 150) 10 Hz
Insulation Resistance (ASTM D-257) 10 ohms
 
RESEL® 502
Insulation of Electrical Materials .and in Cable Jacketing
Higher hardness and lower viscosity than Resel 302.Color: amber or can be pigmented to customer's request.
Polyol : Pre-polymer Ratio 1 : 0,5
Gel time @ 25°C (ASTM D - 2471) 15 - 30 min
Cure time <24 horas
Max cure temperature (ASTM D - 2471) 95°C máx.
Density (20°C ) (ASTM D - 792) 1,0 - 1,2 g/cm
Initial Mixture Viscosity (ASTM D-2669) 1350 - 1450 cps
Hardness (ASTM D - 2240) 40 - 85 Shore "A"
Water Absorption % (ASTM D - 570 ) 1,0%
Volumetric Resistivity (ASTM D-257) > 10 ohms/cm
Dielectric Constant @ 25°C (ASTM D - 150) 10 Hz
Dissipation Factor (ASTM D - 150) 10 Hz
Insulation Resistance (ASTM D-257) 10 ohms